Your Planetcare microfiber filter is easy to install.

Simply download the manual with all the necessary steps  to get your filter up and running in no more than 10 minutes!

No professional help or extra tools required.  

How to install the filter in 10 minutes?

How to change the cartridge?

Step by step:  

Setting up your microfiber filter

STEP 1: Attach the filter holder to your washing machine

PlanetCare 2.0 can be fitted on your washing machine or any other vertical surface near by, as long as it ensures stability and easy access.To attach the filter holder, use the double-sided tape on the filter holder. Do not worry, it is strong enough to hold it in place firmly. You can also attach the holder with two screws (not included).

 

HOW TO ATTACH THE HOLDER

  1. Select a section of the washing machine (or other surface) that is as even as possible.
  2. Thoroughly clean the surface where you’ll attach the holder (this is best done with 70% alcohol).
  3. Be careful not to touch the sticky tape after you’ve removed the protection layer.
  4. Attach the holder to the cleaned surface & press firmly for 5 seconds.

❗ For optimal adhesion, allow the holder to set for 24 hours before attaching the filter.

STEP 2: Attach the holder on your filter

You will need to attach the holder on your PlanetCare 2.0 microfiber filter. The holder does not come pre-installed, because you can install it on either side of your washing machine.

Where is the holder?

You will find the filter holder attached to the wall holder.

LEFT side placement

The holder must be fitted on the right side (hose attachments are in the back). Use the supplied screw.

RIGHT side placement

The holder must be fitted on the left side (hose attachments are in the back). Use the supplied screw.

LOGO placement

Attach the logo on the opposite side.

❗DO NOT tighten the screw without the holder❗

Tightening the screw without the holder can cause irrepairable damage to the filter.

STEP 3: Connect the hoses

PlanetCare 2.0 comes equipped with two hoses that are joined together for easier installation.
Water from the washing machine into the filter comes from the hose marked with “IN”, while water from the filter and into the drain is marked with “OUT”.
Before using the filter, make sure that you connected the hoses securely.

Connect to the filter

Make sure that you correctly attach the hose to the filter - watch for “IN” and “OUT” marks on the connectors and hoses.

Connect to the washing machine and drain

Attach the hose connector to the end of the “IN” hose (the shorter one) and connect it to the drain hose from your washing machine. Connect the end of the “OUT” hose to the drain.

STEP 4: Attach the filter cartridge

Connect the cartridge to the filter housing

PlanetCare 2.0 filter cartridges are attached to the filter housingwith a bayonet attachment that securely holds them in place.

Before using the filter, make sure that the cartridge is attached securely.

Affix the cartridge to the top of the housing and twist it to the right until you feel a slight click. That is the indicator that the cartridge is securely attached.

STEP 5: Attach filter to the holder

Slide the filter onto the filter holder securely. Your PlanetCare 2.0 microfiber filter is now correctly installed and ready to use.

Understanding BYPASS and cartridge replacement indicator

This filter is equipped with an automatic bypass that activates when the cartridge reaches full capacity. When the handle is in raised position, it serves as a visual indicator that it is time to replace the cartridge.The bypass can also be triggered manually when washing clothes made from natural materials.

 Performance adjustment guide

This filter is equipped with an automatic bypass that activates when the cartridge reaches full capacity. When the handle is in raised position, it serves as a visual indicator that it is time to replace the cartridge.The bypass can also be triggered manually when washing clothes made from natural materials.

How to perfectly fine-tune your filter?

Our Chief Science Officer dr. Andrej Kržan explains how to fine tune your PlanetCare 2.0 filter.

Setting ring

PlanetCare 2.0 has a setting ring that adjusts the sensitivity of the automatic bypass. The ring is factory set to the middle (neutral) position.

Factory setting is TOO WEAK

HOW TO FIX IT?

Turn the adjustment wheel one line towards the MAX indicator (to the left). Repeat this until you see an increase in filter cartridge durability. If your machine begins to have difficulty in pumping water (error message on washing machine), turn the wheel back one line towards the MIN indicator.

Factory setting is TOO STRONG

HOW TO FIX IT?

If the bypass indicator doesn't activate automatically after the cartridge is full, the factory setting is too strong. This may lead to wet clothes or difficulty in pumping water (error message on washing machine).

Turn the adjustment wheel one line towards the MIN indicator (to the right), and repeat until the bypass starts activating automatically for smooth operation (properly drained clothes and no error messages on the washing machine).

Your PlanetCare 2.0 filter is ready. HAPPY FILTERING!

Untitled design (56).png__PID:d04f9cc9-4dfe-45eb-99ca-b95c727138ee

If you have any questions or feedback please contact us at support@planetcare.org.