Your Planetcare microfiber filter is easy to install.

Simply download the manual with all the necessary steps  to get your filter up and running in no more than 10 minutes!

No professional help or extra tools required.  

How to install the filter in 10 minutes?

How to change the cartridge?

Step by step:  

Setting up your microfiber filter

STEP 1

Choose a Side & Clean the Surface

  • Pick which side of your washing machine to mount the filter.
  • Wipe the surface with rubbing alcohol to remove dust and grease.

STEP 2

Mount the Holder & Wait 24 Hours

  • Stick the mounting strip (1) to the wall holder (2), then attach it to the surface.
  • Press firmly and wait 24 hours before attaching the filter.

STEP 3

Attach the Filter Holder & Logo

  • Fix the filter holder (6) to the filter head (5) with a screw (8).
  • If necessary, attach the logo (7) to the opposite side of the filter head (5).
  • Choose left or right based on your setup.
  • Do not tighten the screw without the holder❗

STEP 4

Insert the Cartridge & Close the filter

  • Take the assembled head & push the filter cartridge (4) in.
  • Rotate it half a turn until it locks with a click.
  • Attach the filter housing (3) and screw it tightly to prevent leaks.

STEP 5

Connect the Drain Hoses

  • Connect the shorter drain hose (9) to the adapter (10) and attach it to your washing machine’s drain hose. Then, connect the longer hose to your drain.
  • Check the “IN” and “OUT” markings and firmly connect it to the filter.

STEP 6

Attach the Filter (After 24 Hours)

  • Slide the filter into the holder until it clicks into place.

 Performance adjustment guide

This filter is equipped with an automatic bypass that activates when the cartridge reaches full capacity. When the handle is in raised position, it serves as a visual indicator that it is time to replace the cartridge.The bypass can also be triggered manually when washing clothes made from natural materials.

Understanding BYPASS and cartridge replacement indicator

This filter is equipped with an automatic bypass that activates when the cartridge reaches full capacity. When the handle is in raised position, it serves as a visual indicator that it is time to replace the cartridge.The bypass can also be triggered manually when washing clothes made from natural materials.

How to perfectly fine-tune your filter?

Our Chief Science Officer dr. Andrej Kržan explains how to fine tune your PlanetCare 2.0 filter.

Setting ring

PlanetCare 2.0 has a setting ring that adjusts the sensitivity of the automatic bypass. The ring is factory set to the middle (neutral) position.

Factory setting is TOO WEAK

HOW TO FIX IT?

Turn the adjustment wheel one line towards the MAX indicator (to the left). Repeat this until you see an increase in filter cartridge durability. If your machine begins to have difficulty in pumping water (error message on washing machine), turn the wheel back one line towards the MIN indicator.

Factory setting is TOO STRONG

HOW TO FIX IT?

If the bypass indicator doesn't activate automatically after the cartridge is full, the factory setting is too strong. This may lead to wet clothes or difficulty in pumping water (error message on washing machine).

Turn the adjustment wheel one line towards the MIN indicator (to the right), and repeat until the bypass starts activating automatically for smooth operation (properly drained clothes and no error messages on the washing machine).

Your PlanetCare 2.0 filter is ready. HAPPY FILTERING!